1.
Clin Chem Lab Med ; 61(7): 1349-1358, 2023 06 27.
Article in English | MEDLINE | ID: covidwho-2228408

ABSTRACT

OBJECTIVES: The WHO's standardized measuring unit, "binding antibody units per milliliter (BAU/mL)," should allow the harmonization of quantitative results by different commercial Anti-SARS-CoV-2 immunoassays. However, multiple studies demonstrate inter-assay discrepancies. The antigenic changes of the Omicron variant affect the performance of Spike-specific immunoassays. This study evaluated the variation of quantitative Anti-SARS-CoV-2-Spike antibody measurements among 46, 50, and 44 laboratories in three rounds of a national external quality assessment (EQA) prior to and after the emergence of the Omicron variant in a diagnostic near-to-real-life setting. METHODS: We analyzed results reported by the EQA participant laboratories from single and sequential samples from SARS-CoV-2 convalescent, acutely infected, and vaccinated individuals, including samples obtained after primary and breakthrough infections with the Omicron variant. RESULTS: The three immunoassays most commonly used by the participants displayed a low intra-assay and inter-laboratory variation with excellent reproducibility using identical samples sent to the participants in duplicates. In contrast, the inter-assay variation was very high with all samples. Notably, the ratios of BAU/mL levels quantified by different immunoassays were not equal among all samples but differed between vaccination, past, and acute infection, including primary infection with the Omicron variant. The antibody kinetics measured in vaccinated individuals strongly depended on the applied immunoassay. CONCLUSIONS: Measured BAU/mL levels are only inter-changeable among different laboratories when the same assay was used for their assessment. Highly variable ratios of BAU/mL quantifications among different immunoassays and infection stages argue against the usage of universal inter-assay conversion factors.


Subject(s)
COVID-19 , Humans , Reproducibility of Results , COVID-19/diagnosis , SARS-CoV-2 , Antibodies, Viral , Antibodies, Neutralizing
2.
Microbiol Spectr ; 11(1): e0231422, 2023 02 14.
Article in English | MEDLINE | ID: covidwho-2193550

ABSTRACT

Neutralizing antibodies (nAbs) are considered a valuable marker for measuring humoral immunity against SARS-CoV-2. However, live-virus neutralization tests (NTs) require high-biosafety-level laboratories and are time-consuming. Therefore, surrogate virus neutralization tests (sVNTs) have been widely applied, but unlike most anti-spike (S) antibody assays, NTs and sVNTs are not harmonized, requiring further evaluation and comparative analyses. This study compared seven commercial sVNTs and anti-S-antibody assays with a live-virus NT as a reference, using a panel of 720 single and longitudinal serum samples from 666 convalescent patients after SARS-CoV-2 infection. The sensitivity of these assays for detecting antibodies ranged from 48 to 94% after PCR-confirmed infection and from 56% to 100% relative to positivity in the in-house live-virus NT. Furthermore, we performed receiver operating characteristic (ROC) curve analyses to determine which immunoassays were most suitable for assessing nAb titers exceeding a specific cutoff (NT titer, ≥80) and found that the NeutraLISA and the cPass assays reached the highest area under the curve (AUC), exceeding 0.91. In addition, when the assays were compared for their correlation with nAb kinetics over time in a set of longitudinal samples, the extent of the measured decrease of nAbs after infection varied widely among the evaluated immunoassays. Finally, in vaccinated convalescent patients, high titers of nAbs exceeded the upper limit of the evaluated assays' quantification ranges. Based on data from this study, we conclude that commercial immunoassays are acceptable substitutes for live-virus NTs, particularly when additional adapted cutoffs are employed to detect nAbs beyond a specific threshold titer. IMPORTANCE While the measurement of neutralizing antibodies is considered a valuable tool in assessing protection against SARS-CoV-2, neutralization tests employ live-virus isolates and cell culture, requiring advanced laboratory biosafety levels. Including a large sample panel (over 700 samples), this study provides adapted cutoff values calculated for seven commercial immunoassays (including four surrogate neutralization assays and a protein-based microarray) that robustly correlate with specific titers of neutralizing antibodies.


Subject(s)
COVID-19 , SARS-CoV-2 , Humans , COVID-19/diagnosis , Antibodies, Neutralizing , Neutralization Tests , Immunoglobulin G , Antibodies, Viral
3.
Diagnostics (Basel) ; 12(11)2022 Oct 22.
Article in English | MEDLINE | ID: covidwho-2082066

ABSTRACT

Convalescent plasma (CP) has been in use for the treatment of numerous infectious diseases for more than a century, recently also for coronavirus disease 2019 (COVID-19). A major challenge for this treatment is identifying suitable donors with sufficient levels of functional antibodies and to determine the optimal time span for CP donation. In this retrospective study, we analyzed 189 CP donations of 66 donors regarding anti-SARS-CoV-2 anti-S IgG antibody levels. We found a significant correlation between the semi-quantitative SARS-CoV-2 IgG ratio values and in vitro antibody functionality. A time-to-event analysis allowed us to predict the optimal time span of COVID-19 CP donor suitability. We found that high IgG ratio values, which significantly correlate with high in vitro antibody functionality, were suitable for CP donation for a median of 134 days after the first CP donation. Donors with lower IgG ratios were suitable for a median of 53 days. Our data support plasma collection centers to determine optimal points in time for CP donation by means of widely used semi-quantitative laboratory IgG ratio values.

4.
Diagnostics (Basel) ; 12(5)2022 May 10.
Article in English | MEDLINE | ID: covidwho-1869505

ABSTRACT

The COVID-19 pandemic has elicited the need to analyse and store large amounts of infectious samples for laboratory diagnostics. Therefore, there has been a demand for sample storage buffers that effectively inactivate infectious viral particles while simultaneously preserving the viral RNA. Here, we present a storage buffer containing guanidine-hydrochloride that fulfils both requirements. Its ability to preserve RNA stability was confirmed by RT-qPCR, and virus-inactivating properties were tested by tissue culture infectious dose assay. Our data revealed that RNA from samples diluted in this storage buffer was efficiently preserved. Spiking samples with RNase A resulted in RNAse concentrations up to 100 ng/mL being efficiently inhibited, whereas spiking samples with infectious SARS-CoV-2 particles demonstrated rapid virus inactivation. In addition, our buffer demonstrated good compatibility with several commercially available RNA extraction platforms. The presented guanidine-hydrochloride-based storage buffer efficiently inactivates infectious SARS-CoV-2 particles and supports viral RNA stability, leading to a reduced infection risk during sample analysis and an increased period for follow-up analysis, such as sequencing for virus variants. Because the presented buffer is uncomplicated to manufacture and compatible with a variety of commercially available test systems, its application can support and improve SARS-CoV-2 laboratory diagnostics worldwide.

5.
Viruses ; 14(3)2022 03 18.
Article in English | MEDLINE | ID: covidwho-1760846

ABSTRACT

The developmental course of antibodies produced after a SARS-CoV-2 infection has been insufficiently investigated so far. Therefore, the aim of this study was to investigate the dynamics of SARS-CoV-2 antibody levels against the viral nucleocapsid- and spike-protein among Austrian blood donors as a representative group of a supposedly healthy population within the first year after a SARS-CoV-2 infection. The impact of age, sex, vaccination status, AB0-blood group and awareness about the infection was evaluated. Our study shows that the level of anti-N antibodies is declining, while anti-S antibody levels remain stable. Antibodies detected were functional in vitro. Age, sex and blood group do not influence antibody dynamics. However, blood group AB shows significantly lower antibody levels and in vitro functionality compared to other blood groups. Our data reveal that one out of five individuals was not aware of a previous SARS-CoV-2 infection and that the disease course neither affects the level of antibody production nor the in vitro functionality. We also found that 14% of participants show persisting COVID-19-related symptoms for up to nine months. Our results provide valuable insights into the dynamics of the immune response after a SARS-CoV-2 infection in a representative cohort of adult blood donors in Central Europe.


Subject(s)
COVID-19 , SARS-CoV-2 , Adult , Antibodies, Viral , Blood Donors , Humans , Immunologic Tests
6.
Infection ; 49(6): 1187-1194, 2021 Dec.
Article in English | MEDLINE | ID: covidwho-1270552

ABSTRACT

PURPOSE: Frequently the infection with coronavirus 2 (SARS-CoV-2) can be asymptomatic or provoke only mild symptoms. These cases often remain unnoticed, so it is difficult to estimate the actual numbers of infections. Aim of this study was to determine the seroprevalence of anti-SARS-CoV-2 total antibody in Austrian blood donors. METHODS: 20,228 blood donors aged between 18 and 72 years resident in four Austrian federal states were screened for anti-SARS-CoV-2 total antibody between 5th of June and 4th of December 2020. To evaluate the impact of sex, age, AB0-blood group and donation period on the anti-SARS-CoV-2 seroprevalence, multiple logistic regression was done. RESULTS: Our data reveal an anti-SARS-CoV-2 seroprevalence of 2.5% overall, significantly depending on the time point of blood donation: after the first Austrian lockdown the seroprevalence was lower compared to the following months, when the rate was constantly rising. While younger blood donors showed significantly higher seroprevalence, no differences were found concerning sex or AB0 blood group. CONCLUSION: Broad testing strategies are required to better determine the number of SARS-CoV-2 infections. Screening blood donors as a representative group for the adult population could be a valid tool to determine the number of recorded and unrecorded cases of SARS-CoV-2 infection.


Subject(s)
Blood Donors , COVID-19 , Adolescent , Adult , Aged , Antibodies, Viral , Austria/epidemiology , Communicable Disease Control , Humans , Middle Aged , SARS-CoV-2 , Seroepidemiologic Studies , Young Adult
7.
Transfus Med Hemother ; 48(3): 173-174, 2021 May.
Article in English | MEDLINE | ID: covidwho-1153759
8.
Transfus Med Hemother ; 48(2): 99-108, 2021 Mar.
Article in English | MEDLINE | ID: covidwho-835552

ABSTRACT

INTRODUCTION: Antibody-mediated transfusion-related acute lung injury (TRALI) is caused by antibodies against human leukocyte antigens (HLAs) or human neutrophil antigens (HNAs), and is one of the most serious complications associated with transfusion medicine. Prevention strategies like testing allo-exposed female blood donors have not yet been introduced nationwide in Austria. To assess the need and feasibility of routine leukocyte antibody testing, the prevalence of leukocyte-reactive antibodies in an Austrian female donor population was been determined using classical cell-based methods which were compared with a high-throughput bead-based method. METHODS: Sera from 1,022 female blood donors were screened using a granulocyte aggregation test (GAT) and a white blood cell immunofluorescence test (WIFT) after retesting and specification of positive samples by granulocyte immunofluorescence test (GIFT) and monoclonal antibody-specific immobilization of granulocyte antigens (MAIGA). Potential HLA reactivities were confirmed using the microbeads assay LabScreenTM Mixed. The results in 142 donor sera and 38 well-defined reference sera were investigated by the microbeads assay LabScreenTM Multi and compared with classical cell-based methods. RESULTS: Reactivity with either granulocytes and/or lymphocytes was detected in 79 sera (7.7%), with the majority being HLA-specific. Antibodies against HNA were obtained in 7 samples (0.7%). The aggregating potential of the detected antibodies was observed in 9 cases (0.9%). Most of the leukocyte-reactive antibodies occurred at a donor age of between 35 and 59 years (n = 61). LabScreen Multi showed good agreement (κ = 0.767) for HNA antibody detection by cell-based assays, but double/multiple specificities (100% of 7 anti-HNA-1b sera) as well as false-negative results (40% of 15 HNA-3-specific sera) occurred. DISCUSSION: Leukocyte-reactive antibody screening is advised in Austrian female donors for safe blood transfusion, including single-donor convalescent plasma treatment of COVID-19 that may be implemented soon. For the introduction of LabScreen Multi, the combination with GAT should be considered to ensure correct anti-HNA-3a detection.

9.
Transfusion ; 61(1): 12-16, 2021 01.
Article in English | MEDLINE | ID: covidwho-796048

ABSTRACT

BACKGROUND: Transfusion of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) convalescent plasma is a promising treatment for severe coronavirus disease 2019 (COVID-19) cases, with success of the intervention based on neutralizing antibody content. Measurement by serologic correlates without biocontainment needs as well as an understanding of donor characteristics that may allow for targeting of more potent donors would greatly facilitate effective collection. STUDY DESIGN AND METHODS: One hundred convalescent plasma units were characterized for functionally active SARS-CoV-2 neutralizing antibodies, as well as for SARS-CoV-2 binding antibodies, with the intention to establish a correlation between the functionally more relevant neutralization assay and the more accessible enzyme-linked immunosorbent assay (ELISA). Donor demographics such as COVID-19 severity, age, and sex were correlated with antibody titers. RESULTS: A mean neutralization titer 50% of 230 (range, <8-1765) was seen for the 100 convalescent plasma units, with highly significant (P < .0001) yet quantitatively limited (R2 = 0.2830) correlation with results of the ELISA. Exclusion of units with particularly high titers (>500) from analysis improved correlation (R2 = 0.5386). A tendency of higher-titer plasma units from donors with increased disease severity, of advanced age, and of male sex was seen, yet the functional relevance of this difference is questionable. CONCLUSION: The ELISA-based correlation to neutralization titer enabled a threshold proposal that could be used to eliminate lower-titer units from the clinical supply for COVID-19 treatment. Disease severity may be associated with the development of higher titers of neutralizing antibodies, although larger case numbers will be needed for additional confirmation.


Subject(s)
COVID-19/therapy , COVID-19/virology , SARS-CoV-2/pathogenicity , Blood Donors , COVID-19/immunology , Enzyme-Linked Immunosorbent Assay , Humans , Immunization, Passive/methods , SARS-CoV-2/immunology , COVID-19 Serotherapy
10.
J Clin Virol ; 129: 104540, 2020 08.
Article in English | MEDLINE | ID: covidwho-634530

ABSTRACT

Since the emergence of SARS-CoV-2 numerous antibody assays have become available, demonstrating different performance characteristics. This study focused on a quantitative correlation between different commercial assays and a neutralization test (NT). Comparative data is needed as a basis for the production of convalescent plasma and potential interpretations COVID-19 immunity. Sera of 100 SARS-CoV-2 convalescent plasma donors were collected and SARS-CoV-2 antibodies were characterized using three different IgG-ELISAs (EUROIMMUN IgG and NCP-IgG ELISA, Wantai ELISA), two CLIA (Elecsys, LIAISON) and two lateral flow tests (MEDsan IgM/IgG-Rapid-Test, Wantai Rapid Test) and subsequently correlated to neutralization titers. The Wantai ELISA and the Elecsys provide the highest sensitivities in this sample (98 and 95 percent respectively). Titers with the best overall quantitative correlation to the NT titer were obtained with the Euroimmun IgG ELISA assay (Rho=0.759) and the Wantai ELISA assay (Rho=0.729). An infection without fever and negative or weakly positive reactions in the Wantai Rapid test were negative predictive factors for NT titers >1:200 (negative predictive value of 92 % and 92 % respectively, combination of both 100 %). The Wantai ELISA titer could be a suitable substitute for NT. An adequate pooling strategy of plasma units additionally could compensate deviations of individual antibody titers.


Subject(s)
Antibodies, Viral/blood , Betacoronavirus/immunology , Clinical Laboratory Techniques/methods , Coronavirus Infections/diagnosis , Pneumonia, Viral/diagnosis , Serologic Tests/methods , Adolescent , Adult , Aged , Antibodies, Neutralizing/blood , COVID-19 , COVID-19 Testing , Female , Humans , Immunoglobulin G/blood , Male , Middle Aged , Pandemics , Predictive Value of Tests , SARS-CoV-2 , Sensitivity and Specificity , Young Adult